Stainless Steel Sample Loops > 크로마토그래피

본문 바로가기

쇼핑몰 검색

Stainless Steel Sample Loops 요약정보 및 구매

공급업체 IDEX

Stainless Steel Sample Loops 

 

 

These high quality stainless steel sample loops have burr-free, square-cut ends to ensure a flush connection to valve ports. The size designations of loops are nominal. The actual volumes can differ from the theoretical designations because the ID tolerance varies depending on the tubing tolerance of the metal tubing bore. Accuracy of large metal loops (1.0 mm, 0.040” bore) is about ±5%, intermediate loops (0.5 mm, 0.020” bore) ±10%, and small loops (0.2 mm, 0.007” bore) ±30%. Since both standards and unknowns are usually analyzed using the same sample loop, knowledge of the actual, accurate volume is rarely needed. If the sample loop volume must be known, it is best to calibrate the loop in place on the valve so the flow passages in the valve are also taken into account. An alternative to calibration is to use a dual mode injector and partial-filling method of loading. See the “Sample Loop Loading” Application Note on page 133. Model 7725 Injector loops are not interchangeable with loops for the model 7125. The port angle for the 7725 is 30° whereas the port angle for the 7125 is 20° requiring the loops to have a different shape. Model 8125 Micro-Scale Sample Injector requires special loops in the 5.0 µL to 50 µL range. The 8125 sample loops are made with 0.5 mm (0.020”) OD tubing 

Stainless Steel Sample Loops  

 

 

 How to Properly Install Sample Loops: Stainless Steel


Stainless steel sample loops are supplied with fittings that are not swaged onto the tube. It is important that the loop be completely bottomed in the injector port before the ferrule is swaged onto the tube. The depth of the tubing holes may vary slightly from port to port and from valve to valve. A fitting made up in one port may leave a small cavity in another port. The cavity causes high dispersion and peak distortion such as fronting, tailing, or broadening. It is good practice to label loop ends so they will be replaced in the same, respective ports that were used in swaging the ferrules. Hint: swaging ferrules separately on each side, into each respective valve port makes loop installation easier.

 


 

▶ 주문정보표
제품번호 품명 선택 수량
70205uL,SS,Sample Loop,20 deg /EA
702110uL,SS,Sample Loop,20 Deg /EA
702220uL,SS,Sample Loop,20 /EA
702350uL,SS,Sample Loop,20 deg /EA
7024100uL,SS,Sample Loop,20 deg /EA
7026500uL,SS,Sample Loop,20 deg /EA
70271mL,SS,Sample Loop,20Deg /EA
70282mL,SS,Sample Loop,20 Deg /EA
70295mL,SS,Sample Loop,20 deg /EA
1876Sample Loop SS 10mL Assy /EA
3065-0182mL,SS,Sample Loop, 1/8 /EA
3065-0195mL,SS,Sample Loop, 1/8 /EA
3065-02310mL,SS,Sample Loop,1/8 /EA
3065-02520mL,SS,Sample Loop,1/8 /EA
7755-0205uL,SS,Sample Loop,30 Degree /EA
7755-02110uL Sample loop /EA
7755-02220uL,SS,Sample Loop,30 deg /EA
7755-02350uL,SS,Sample Loop,30 deg /EA
7755-024100uL,SS,Sample Loop,30 deg /EA
7755-025200uL,SS,Sample Loop,30 deg /EA
7755-026500uL,SS,Sample Loop,30 deg /EA
7755-0271mL,SS,Sample Loop,30 Degree /EA
7755-0282mL,SS,Sample Loop,30 deg /EA
7755-0295mL,SS,Sample Loop,30 deg /EA
1876Sample Loop SS 10mL Assy /EA
80205uL SS Loop for 8125/8126 /EA
802110uL SS Loop for 8125/8126 /EA
802220uL SS Loop for 8125/8126 /EA
802350uL SS Loop for 8125/8126 /EA

관련상품

등록된 상품이 없습니다.

Information

주식회사 시마즈 사이언티픽 코리아 | 대표자 : 야마다 타케시 | 사업자등록번호 : 307-87-01124
주소 : (우06108) 서울시 강남구 언주로 609 9층(논현동, Pax타워)

Copyright .. Shimadzu Scientific Korea Corp.

고객센터

02-540-0078

spechrom@shimadzu.co.kr
월-금 09:00 - 18:00 / 점심시간 12:00 - 13:00